Curt Blank's

Solar Powered Home
For 20160808

Archived Inverter Stats
Parameter Current 
Value
 Minimum 
Value
 Maximum
Value

West Array Voltage 107.70 98.28 260.04    VDC
West Array Current 0.01 0.01 7.48    ADC
West Array Power 0.99 0.61 1578.91    Watts
East Array Voltage 0.00 0.00 254.41    VDC
East Array Current 0.00 0.00 7.35    ADC
East Array Power 0.00 0.00 1537.55    Watts
Total PV Panel Power 0.99 0.61 3116.46    Watts
Watts Per Minute 0.00 0.00 54.00    Watts
Solar Radiation 5 0 839    W/m2
Sun Altitude Angle -0.94 -1.14 62.86    °
Sun Azimuth Angle 112.75 0.24 113.19    °
Sun PV Incidence Angle 105.14 12.86 105.56    °
Outdoor Temperature 75.10 60.40 82.20    °
Grid Voltage 0.00 0.00 245.80    VAC
Grid Current  (Note 1) 0.00 -0.05 12.06    AAC
Grid Power  (Note 1) 0.00 -23.01 2929.33    Watts
Grid Power  (Note 2) 0.00 -13.05 2941.48    Watts
Grid Frequency 0.00 0.00 60.04    Hz.
Inverter Heatsink Temperature 0.00 0.00 72.31    °C
Inverter Internal Temperature 0.00 0.00 50.01    °C
Inverter Efficiency 0.00 0.00 95.34    %
Inverter Efficiency Losses 0.99    Watts
Inverter Run Time 14:14    hh:mm
Solar Radiation Average 467.06    W/m2
West Array Average Power 744.850    Watts
East Array Average Power 699.280    Watts
PV Panel Average Power 1444.130    Watts
Grid Average Power  (Note 1) 1383.540    Watts
OffPeak Power Produced (This day) 0.046    KWh
OnPeak Power Produced (This day) 19.047    KWh
Total Power Produced (This day) 19.093    KWh

Notes:
  1.) Inverter output reported
  2.) Inverter output calculated
  • Run Time is based on valid communication with the Inverter and full data returned. Communication and data returned can be sporadic during morning startup and evening shutdown when the PV Power is not adequate for the Inverter to run.
  • Grid Power i.e. Inverter Power Output, as reported by the Inverter appears to be lower then the calculated power (Grid Output Voltage X Grid Output Current).
  • The response of the Solar Radiaion detector lags by minutes at times the reponse that the PV Panels have to sunlight, so the PV Power Output may be high when the Solar Radiation looks low and vise versa.

  • Back to Solar Powered Home [08] 8th, 2016
    Solar Powered Home

    All content Copyright © 2006-2016 Curtronics.com Curtis J. Blank
    May not be used in any form without permission

    Tux, the Dancin' Fool - Hit ESCAPE to stop the dancin' Best yet! Apache Web Server Tux, the Dancin' Fool - Hit ESCAPE to stop the dancin'